Hi,
The message
"Unable to plot empty GSA results. Check if warnings were issued when running the global sensitivity analysis."
indicates that SimBiology was not able to compute GSA results. A common cause is, when using MPGSA, a misspecified classifier. Can you confirm if the Messages section at bottom of the GSA program in SimBiology Model Analyzer contains the following warning?
"Evaluation of classifier(s) <your classifier> unsuccessful. Classifier expressions must evaluate to logical vectors of the same length as the number of valid parameter samples."
If this is not the case, we need to investigate further; can you post the warnings shown in the Messages section?
If the root cause is the classifier, can you please check if the classifier is specified correctly? Here is the documentation that may help. The relevant section is "Each classifier must evaluate to a logical vector of the same length as the number of parameter samples. [...] a classifier expression are evaluated as a matrix with columns containing time courses of the simulated quantity values. Each column represents one sample. Each row represents one output time."
The documenation also contains an example. You could also post the classfier here so we can take a look. If do not wish to post your classfier publicly, feel free to contact MathWorks Technical Support. -Florian