Question
I am currently working with Simulink and out of the sudden, I am unable to change the Model Configuration Parameters.
I am currently working with Simulink and out of the sudden, I am unable to change the Model Configuration Parameters. Whether I...
13 days ago | 0 answers | 0
0
answersQuestion
I want to customize a 34cc vapor injection compressor model in Simscape. How do I go about it? How can I simulate the vapor injection process and the intermediate compression
Hello,I want to customize a 34cc vapor injection compressor model in Simscape to simulate and compare the performance of a vapor...
7 months ago | 0 answers | 0
0
answersQuestion
Two-phase flow control valve
Hello, is there a two-phase flow regulator in Simscape that does not change the pressure on both sides?
1 year ago | 1 answer | 0
1
answerQuestion
The particle swarm optimization algorithm optimizes the scale factor and quantization factor of the fuzzy PID controller
I want to use the particle swarm optimization algorithm to optimize the scale factor and quantization factor of the fuzzy PID co...
1 year ago | 1 answer | 0
1
answerQuestion
The element 1 in SCDPotentialLinearizationIOs structure is not referring to an existing block in the model。
Hello,I don't know where to operate when adjusting the PI control of the model, and suddenly the following error appears: The el...
1 year ago | 1 answer | 0
1
answerFuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello,I don't seem to have tried the peak you mentioned, I'm not sure what conditions are suitable for him, I adjusted his param...
1 year ago | 0
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I don't have his differential equations here, I'm using the compressor components in Simscape and using Simluink to control the ...
1 year ago | 0
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I haven't tried this before, I'm a direct control of the actuator, but I feel that this phenomenon seems a little strange. It's ...
1 year ago | 0
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello, I found that the model you built does not seem to initialize the PID parameters, and directly input the output of the fuz...
1 year ago | 0
Question
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
In 'EV_Thermal_Management_wendukongzhi_zhileng/Controls/Compressor Control/ÿÿÿÿ/Fuzzy Logic Controller', input 2 expects a val...
1 year ago | 2 answers | 0
2
answersQuestion
I want to use a solenoid valve to achieve two-phase flow on/off
Hello,I want to use a solenoid valve to achieve two-phase flow on/off, I tried to use the Orifice (2P) module, but its cross-flo...
2 years ago | 1 answer | 0
1
answerQuestion
2P-2P Heat Exchanger
I am trying to build a two-phase flow heat exchanger (2P-2P), which means that the heat exchanger on both sides of the heat exch...
2 years ago | 1 answer | 0
1
answerQuestion
two-phase flow 4-way valve
I want to build a two-phase flow 4-way valve using Simscape, what do I do?
2 years ago | 1 answer | 0
1
answerQuestion
Why is my electronic expansion valve not working
Hello, I am building a model of a heat pump air conditionerI am trying to use an electronic expansion valve for throttling, but ...
2 years ago | 0 answers | 0
0
answersQuestion
Simscape how to set up a multi-process evaporator or condenser
Hello, I want to create a parallel flow microchannel condenser with four processes but there doesn't seem to be a similar module...
2 years ago | 1 answer | 0
1
answerQuestion
Custom quasi-secondary compressor models report errors
I want to add a make-up port to the controllable mass flow element, but when I run it he gets the error: Cannot find parameter '...
2 years ago | 1 answer | 0
1
answerQuestion
Heat Pump Air Conditioner
I'm trying to build a make-up enthalpy heat pump air conditioner with Simscape but I don't know how to start, does anyone know h...
2 years ago | 1 answer | 0