Error calculating specific heat and constant pressure
Show older comments
I get an error when compiling my Simscape model using a real gas specification.
Elements of Specific heat at constant pressure table must be greater than (Temperature) * (Specific volume) * (Isothermal bulk modulus) * (Isobaric thermal expansion coefficient)^2.
I verified my real gas data using the expression:
cv_TLU2 = cp_TLU2 - repmat(T_TLU2(:), 1, n) .* alpha_TLU2.^2 .* beta_TLU2 ./ rho_TLU2;
In all cases the value that I get from this is positive and also in all cases Cp is greater than the product "(Temperature) * (Specific volume) * (Isothermal bulk modulus) * (Isobaric thermal expansion coefficient)^2".
In fact I checked the output of that expression against known Cv data for this gas and it it matches exactly so I can't understand how Simscape finds an error with this.
Accepted Answer
More Answers (0)
Categories
Find more on Gas Models in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!