HDL Coder no clock signals detected

Hello,
I was wondering how to set clock signals for MATLAB code. I noticed that the demo (corner detection found in HDL coder demos image processing) had a clock signal: clk | BUFGP | 1701
as well as an asynchronous control signal:
reset | IBUF | 861
Hence, I was wondering how to set these in my own design. I am not using simulink and want to find out how to set clock in MATLAB code.
Thank you, Alvin

Answers (1)

Tim McBrayer
Tim McBrayer on 22 Apr 2013
MATLAB code is untimed, sequential code. HDL Coder synthesizes this code to a cycle-accurate HDL implementation. The clock and reset signals are not present in the original MATLAB code in any form. They are synthetic signals, added to the user design.

2 Comments

In this case could you explain for the demos how during synthesis a clock was detected?
Any state data, such as persistent MATLAB variables or a delay object instance, indicates state. When there is state in the design, HDL Coder infers a clock and reset signal.

Sign in to comment.