Erro due to different sample time

1 view (last 30 days)
stephane teiguim
stephane teiguim on 19 May 2020
Answered: Sameer on 6 May 2025
Hello evryone
My simulink miodel is not able to compile because i have inside of it two different block , the first block is scheduling at 20ms and the second is scheduling ar 100ms the problem is that the output of the first block is the input of the second one .I dont know how figure out wih it.
Thanks for your help

Answers (1)

Sameer
Sameer on 6 May 2025
When the output of a faster block (20 ms) is used as the input to a slower block (100 ms), Simulink needs to know how to handle the rate transition. If not handled properly, you get compilation errors.
Insert a "Rate Transition" block between your 20ms and 100ms blocks. Connect the output of the 20ms block to the Rate Transition, then connect that to the 100ms block. Set the Rate Transition block’s output sample time to 0.1 (100ms).
Hope this helps!

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!