method “block.Set​PreCompOut​portInfoTo​Dynamic” in Level 2 S function

Hi,
In Level-2 S function there is a method “block.SetPreCompOutportInfoToDynamic” which sets the output properties to be inherited. I think it works fine for the case with only one input. What about the case with two inputs? From which input will the output be inherited?
Thanks Senmeis

2 Comments

It should depend on the way the inputs are evaluated for output calculation.
Consider a L-2 S Function which simply multiplies the values from its two input ports. The output properties would depend on the values passed in. For example, if one input port passes in a single input and other passes in a double input, the output would then implicitly be determined to be a double type.
Thank you very much.
Senmeis

Sign in to comment.