Why are my simulink initial conditions sometimes not met, despite high priority?

I set the initial temperature of a Simscape thermal mass to 303K and put a temperature sensor on it. Solver is set to start with steady state. Still, the temperature of this mass is 293 at t=0s and there are no warnings or errors reported in the diagnostics viewer. Large screenshot is attached.tf.PNG

1 Comment

Hi,
I tried to reproduce the mentioned initial conditions on a simple model and it is working as expected.Please provide the model, so that a workaround may be provided.

Sign in to comment.

Answers (1)

When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulation. It does not use the initial targets in set in the blocks.

Categories