Clear Filters
Clear Filters

How can I pass buses to referenced model?

17 views (last 30 days)
Marco Bottani
Marco Bottani on 8 Jul 2019
Answered: Maadhav Akula on 30 Jul 2019
Hello,
I've a subsystem that I want to convert in a Referenced model, this subsystem have 2 buses as input a 1 as output.
As long as I use subsystem everthing works fine, but when I try to convert it in a Referenced model this error appears:
Invalid setting in 'xxx/currentCtrlOut' for parameter 'OutDataTypeStr'.
Caused by:
  • Error evaluating parameter 'OutDataTypeStr' in 'xxx/currentCtrlOut'
  • Cannot resolve variable 'currentCtrlOut'
  • Variable 'currentCtrlOut' has been deleted from base workspace.
How can I solve it?
Thanks a lot for the help

Answers (1)

Maadhav Akula
Maadhav Akula on 30 Jul 2019
From your question I am assuming that currentCtrlOut is the output from the referenced model and I think that currentCtrlOut variable is declared in the referenced model (which makes it local to the Model Worksapce), in a Reference model the Model Workspace is cleared immediately after computing that model. To avoid this, please refer to the link below:
If that does not solve your issue please also refer to this link:
Hope it helps!

Products


Release

R2018a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!