Simulation Data Inspector (SDI) does not show signals marked for streaming from Simulink model running on Speedgoat
24 views (last 30 days)
Show older comments
MathWorks Support Team
on 12 Feb 2019
Edited: MathWorks Support Team
on 14 Mar 2025
I marked some signals for logging and ran my model in External Mode ("Run on target") on a Speedgoat Simulink Real-Time target. Everything appears to work correctly except that there are no signals shown in SDI during the simulation.
Accepted Answer
MathWorks Support Team
on 14 Mar 2025
Edited: MathWorks Support Team
on 14 Mar 2025
1) Make sure that the Simulink Data Inspector is working as expected by running the example below which does not use Simulink Real-Time.
2) Try the shipped example of logging signal in SDI for real-time models:
3) Check the MATLAB Command Window for warnings about non-observable signals when you are running your own model. See the following post for details:
https://www.mathworks.com/matlabcentral/answers/773802-why-am-i-unable-to-log-or-stream-signals-when-my-application-is-running-on-hardware-external-mode-a
4) If the above steps are all good except signal logging in SDI, revise the firewall and antivirus settings on your development computer: