Running Simulink Coder gives warning 'GenSettings must be initialized'
Show older comments
I am currently running the latest version of matlab. in my model i combined 3 different block libraries. Simulink, SimScape and RF libraries. When i try to build my model using the build button i get an error 'GenSettings must be initialized'. I am attempting to build my model as a standalone application using simulink coder. I can simulate the model using the play button but building the model is the one generating the error.
Answers (2)
Nick Sarnie
on 30 Jun 2018
Edited: Nick Sarnie
on 30 Jun 2018
1 vote
If you have "clear all" in any model callbacks, especially the "Init Fcn" model callback, please remove that and try to generate code again.
If you still experience the error, please contact Technical Support.
1 Comment
Sumit Shrestha
on 28 Nov 2018
It solved my problem. Thanks!
Matthew Overlin
on 30 Jun 2018
0 votes
Same error here. Ubuntu 18.04, Matlab 2018a. Can anybody help here?