Loading model into older version of Simulink

Hello. I am loading a Simulink model created using Matlab 2015b into the older version of Simulink which comes with Matlab 2011b. When I do, I get a range of warnings. However the model works fine. My question is if these warnings are due to the version mis-match:
line does not have a parameter named 'ZOrder'
BusCreator block does not have a parameter named 'InheritFromInputs'
block_diagram does not have a parameter named 'ShowVisualizeInsertedRTB'
block_diagram does not have a parameter named 'ShowMarkup'
block_diagram does not have a parameter named 'PauseTimes'
block_diagram does not have a parameter named 'NumberOfSteps'
block_diagram does not have a parameter named 'SnapshotBufferSize'
block_diagram does not have a parameter named 'SnapshotInterval'
block_diagram does not have a parameter named 'NumberOfLastSnapshots'
block_diagram does not have a parameter named 'ExplicitPartitioning'
So, are these warnings due to version differences or do I have another problem om my hand?:)
Best Regards MC

Answers (1)

Yes, these warnings are due to a version mismatch. You can eliminate these warnings by opening the model in R2015b and then using the Simulink File -> Export model option to save the model in R2011b format.

Categories

Find more on Modeling in Help Center and File Exchange

Products

Asked:

MC
on 22 Nov 2017

Answered:

on 26 Nov 2017

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!