connecting pv array shows no output
9 views (last 30 days)
Show older comments
when i connect a pv array block in my model with module data user defined then i found output of module to be nan, but when i click on robust discrete model i got some output but in both the cases my scope is completely blank, a complete white screen shows. why & how this happens.
0 Comments
Answers (1)
Ayush
on 9 Dec 2025 at 4:25
Hi Jyotiprakash,
This issue occurs because the electrical ports on the "PV Array" block are physical conserving ports, not regular output ports. If you connect them only to a "Voltage Measurement" block without forming a complete electrical circuit (for example, connecting to a battery, load, or grid), the simulation cannot solve the network, and you will see NaN values.
To resolve this, connect the PV Array’s electrical ports as part of a complete circuit with a voltage source or load. For reference, you can look at the following documentation to understand proper PV Array connections:
Hope this helps!
0 Comments
See Also
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!