PWM signal goes to zero when using PID controller after MPPT (P&O) in PV system

7 views (last 30 days)
I built a PV solar system in Simulink with an MPPT controller using the Perturb and Observe (P&O) algorithm. The system works fine with only the MPPT .
Then, I added a PID controller to improve performance. I set the error input to the PID as:
error = V_ref (from MPPT duty output) - V_PV (from PV array)
The PID output is then sent to the PWM Generator (DC-DC), which controls the IGBT in a buck converter. However, after adding the PID, the PWM signal becomes zero, and the system stops working properly — no switching occurs, and the output voltage drops.
  1 Comment
Adarsh
Adarsh on 4 Jun 2025
Can you verify if the output of PID controller is in valid range for the PWM generator's "Duty Cycle" i.e [0, 1]?

Sign in to comment.

Answers (1)

Sabin
Sabin on 6 Jun 2025
Most likely the output of the PID controller is <=0 which will result in PWM signal to be 0. Double check the corectnes of the control structure and if there is any sign mismatch.