error after 24 seconds in model
    1 view (last 30 days)
  
       Show older comments
    
 component divide
component divide    % PS Divide :0.75
    % This block divides the first input signal by the second one:
    % y = u_1 ./ u_2
    %
    % All connections are physical signal ports.
    inputs
        I1; % Left input signal (numerator)
        I2; % Right input signal (denominator)
    end
    outputs
        O; % Output signal (result of division)
    end
    equations
        epsilon = 1e-1;  % Small value to prevent division by zero
        O = I1 ./ max(I2, epsilon);  % Apply regularization to denominator
    end
end

0 Comments
Answers (1)
  Suraj Kumar
 on 1 Dec 2024
        The error that you are encountering during simulation of the model can be eliminated by using the following steps. 
You can select 'Use local solver' in the ‘SolverConfiguration’ block if it is present in the model.  
This allows Simscape and physical network components to utilize a specialized local discrete solver. The local solver treats the physical network as a stiff system, using an implicit solver to iteratively find the solution for the next time step with an algebraic solver. 
To learn more about making optimal solver choices for physical simulation, you can refer to the following documentation: 
Hope it helps!
0 Comments
See Also
Categories
				Find more on Trimming and Linearization in Help Center and File Exchange
			
	Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!