Simulink Desktop Real-Time issue under Matlab R2024a

I am trying to run SLDRT models with Matlab/Simulink R2024a.
The models were functionnal under Matlab R2023a
In Matlab/Simulink R2024a, the analog inputs of my NI-PCI 6321 card update at a very slow pace and the analog outputs never update.
To ensure that this is not a Windows 11 issue, I reverted back to Matlab/Simulink R2023a and the old models still worked fine.
Is there a real issue or am I missing something?

4 Comments

It is advisable to review the changes between R2023b and R2024a. The release notes can be accessed here: https://www.mathworks.com/help/sldrt/release-notes.html?startrelease=R2023b&endrelease=R2024a&rntext=&groupby=release&sortby=descending
There is a particular update in R2024a that may impact the board. It would be beneficial to check if the specific feature affected is in use.
Could the model be shared for testing and to explore potential workarounds?
Thanks for the offer.
The case has been solved by MathWorks technical support.
@Jean-Jacques, Will it be possible to mention the solution here so that other people facing similar issue can refer to this ?

Sign in to comment.

Answers (1)

The problem was identified by Matlab tech support as "[...] a bug in the Slider Gain block on MATLAB R2024a. This bug pertains particularly to the slider widget in the block's mask dialog."
The solution : "This bug has been fixed in our newest release, R2024b. [...] I would recommend you download and install MATLAB R2024b [...]."
I haven't try this solution yet but will do in the next few weeks.