24 hour chs for loads with evcs and pv wt
4 views (last 30 days)
Show older comments
i want simple code for optimizer to reduce power loss in system consists of industrial,commercial and residential loads with PV ,load flow
0 Comments
Answers (1)
Namnendra
on 12 Sep 2024
Hi Rose,
Creating an optimizer to reduce power loss in a system with industrial, commercial, and residential loads, along with photovoltaic (PV) systems, involves several steps. This task requires a load flow analysis and optimization technique to adjust the power distribution efficiently. Below is a simplified example using MATLAB, focusing on the core idea of integrating load flow analysis with an optimization routine.
Simplified Approach
1. Model the System:
- Define the power system components: loads, PV systems, and electric vehicle charging stations (EVCS).
- Use a power flow solver to calculate power losses.
2. Set Up the Optimization Problem:
- Define the objective function to minimize power losses.
- Use constraints to ensure system stability and operational limits.
3. Use an Optimization Solver:
- Implement an optimization algorithm like `fmincon` to solve the problem.
Example Code
% Define system parameters
num_hours = 24; % 24-hour simulation
num_buses = 5; % Example number of buses
load_profiles = rand(num_buses, num_hours); % Random load profiles as an example
pv_profiles = rand(num_buses, num_hours) * 0.5; % Random PV profiles
% Objective function to minimize power loss
function loss = powerLossObjective(x, load_profiles, pv_profiles)
% x is the vector of optimization variables (e.g., power dispatch)
% Calculate net load after PV generation
net_load = load_profiles - pv_profiles .* x;
% Simplified power loss calculation (example)
loss = sum(sum(net_load.^2)); % Quadratic losses as an example
end
% Constraints function
function [c, ceq] = powerConstraints(x)
% Example constraints: limits on x, power balance, etc.
c = [];
ceq = sum(x) - 1; % Example constraint: total PV dispatch should be equal to 1
end
% Initial guess for optimization variables
x0 = ones(num_buses, num_hours) * 0.5;
% Set optimization options
options = optimoptions('fmincon', 'Display', 'iter', 'Algorithm', 'sqp');
% Run optimization
[x_opt, loss_min] = fmincon(@(x) powerLossObjective(x, load_profiles, pv_profiles), ...
x0, [], [], [], [], zeros(size(x0)), ones(size(x0)), ...
@powerConstraints, options);
% Display results
disp('Optimized PV dispatch:');
disp(x_opt);
disp(['Minimum power loss: ', num2str(loss_min)]);
Explanation
- Load and PV Profiles: The example uses random data for load and PV profiles. In a real scenario, you would replace this with actual data.
- Objective Function: The power loss is modeled as a quadratic function of the net load. This is a simplification; a detailed model would use load flow analysis.
- Constraints: An example constraint ensures that the total PV dispatch is normalized. You can add more constraints based on system requirements.
- Optimization Routine: The `fmincon` function is used with Sequential Quadratic Programming (SQP) to solve the optimization problem.
Notes
- Load Flow Analysis: For a realistic implementation, integrate a load flow solver such as `MATPOWER` or Simulink Power Systems.
- Detailed Modeling: Consider detailed modeling of the grid, including line impedances, transformer ratings, and operational constraints.
- EVCS Integration: Incorporate electric vehicle charging patterns and constraints if necessary.
This code provides a basic framework. For a more comprehensive solution, you would need to expand the model to include detailed power system dynamics and constraints.
Thank you.