problem to solar maximum power for resistive load

first figure showed power is 315.1w which is maximum power for this solar panel.
when I changed irradiance from 1000 to 500, figure as blow
How come the power is only 87.59w (load keeps unchanged)?
How can I always find maximum point power as load is fixed but irradiance or temperature varys?
thanks.

 Accepted Answer

You have a constant load in the figure, and you are calculating the power P = IV, so changing the irradiance will always change the output current from the cell thus the voltage, which will vary the power calculated and the load will still be constant.

2 Comments

Kian
Kian on 9 Jan 2023
Edited: Kian on 9 Jan 2023
thanks in advance. then How do we make solar panel always track the mpp when irreadiance or temperature changes no matter if the load changes?
You need a system with a feedback and a controller, a controller algorithm can be something like this: MPPT Algorithm - MATLAB & Simulink (mathworks.com)

Sign in to comment.

More Answers (0)

Categories

Tags

Asked:

on 8 Jan 2023

Commented:

on 9 Jan 2023

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!