Simulink signal is double when it should be logical.
23 views (last 30 days)
Show older comments
I'm using a delay block to feed a signal back into a matlab function block. The signal is a logical. It is only ever set via true or false, I never use numbers. Simulink things this is a double for some reason, and I can't even change it to a single. I've tried setting the starting value in the delay block to false or logical(0), but neither work.
0 Comments
Accepted Answer
Paul
on 22 Oct 2022
Hi Sam,
Set the initial condition of the Delay block (or Unit Delay block, not sure which is being used) to false or true as desired.
In the Matlab Function block editor, click on Edit Data to open the Symbols pane. Ensure the input signal to the block that is the feedback from the Delay block has the Type explcitly set to Boolean (not Inheritied). This worked for me, with a Matlab Function block code being
function y = fcn(u)
y = ~u;
end
However, I don't understand why Matlab couldn't figure it all out once the IC of the delay block was specified as a Boolean.
More Answers (0)
See Also
Categories
Find more on Sources in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!