Check safety-related diagnostic settings for Stateflow
Check ID:
mathworks.hism.hisl_0311
Check safety-related diagnostic settings for Stateflow®
Description
This check verifies that model configuration parameters are set optimally for Stateflow for a safety-related application.
Available with Simulink® Check™.
This check requires Stateflow license.
Results and Recommended Actions
Condition | Recommended Action |
---|---|
The diagnostic that detects whether a chart configuration leads to
unwanted backtracking during simulation is set to
none or
warning . | In the Configuration Parameters dialog box, set Unexpected backtracking or set the parameter
|
The diagnostic that detects whether a chart configuration has blocks
that connect to chart input ports do not initialize their outputs during
initialization is set to none or
warning . | In the Configuration Parameters dialog box, set Invalid input data access in chart initialization or set the parameter
|
The diagnostic that detects whether a chart has an unconditional
default transition to a state or a junction is set to
none or
warning . | In the Configuration Parameters dialog box, set No unconditional default transitions or set the parameter
|
The diagnostic that detects whether a chart contains a transition
that loops outside of the parent state or junction is set to
none or
warning . | In the Configuration Parameters dialog box, set Transition outside natural parent or set the parameter
|
The diagnostic that detects whether a chart is constructed on a valid
execution path is set to none or
warning . | In the Configuration Parameters dialog box, set Unreachable execution path or set the parameter
|
The diagnostic detects that the parameter Undirected event
broadcasts is set to none or
warning . | Set Undirected event broadcasts in the
Configuration Parameters dialog box or set the parameter
SFUndirectedBroadcastEventsDiag to
error . |
The diagnostic detects that the parameter Transition action
specified before condition action is set to
none or
warning . | Set Transition action specified before condition
action in the Configuration Parameters dialog box or set
the parameter SFTransitionActionBeforeConditionDiag
to error . |
The diagnostic that detects that the parameter
Read-before-write to output in Moore chart is
set to none or
warning . | Set Read-before-write to output in Moore chart
in the Configuration Parameters dialog box or set the parameter
SFOutputUsedAsStateInMooreChartDiag to
error . |
The diagnostic detects that the parameter Absolute time
temporal value shorter than sampling period is set to
none or
warning . | Set Absolute time temporal value shorter than sampling
period in the Configuration Parameters dialog box or set
the parameter
SFTemporalDelaySmallerThanSampleTimeDiag to
error . |
The diagnostic detects that the parameter Self transition
on leaf state is set to none
or warning . | Set Self transition on leaf state in the
Configuration Parameters dialog box or set the parameter
SFSelfTransitionDiag to
error . |
The diagnostic detects that the parameter
Execute-at-Initialization disabled in presence of input
events is set to none or
warning . | Set Execute-at-Initialization disabled in presence of input
events in the Configuration Parameters dialog box or set
the parameter SFExecutionAtInitializationDiag to
error . |
Action Results
Clicking Modify Settings configures model diagnostic settings that apply to solvers and that can impact safety.
Capabilities and Limitations
Does not run on library models.