Check if tunable block parameters are defined as named constants
Check ID:
mathworks.jmaab.jc_0645
Guideline: jc_0645: Parameter definition for calibration
Description
Checks if tunable block parameters are defined as named constants.
Block parameters that are targets of calibration must be defined as named constants. These parameters are the exception:
Initial value when set to 0
Increment, decrement value when set to 1
Arithmetic expressions
Note
Literals are used for array indexing.
This table lists the Simulink® blocks and respective parameters supported:
| Blocks | Supported Parameters |
|---|---|
| Backlash | BacklashWidth,InitialOutput |
| Bias | Bias |
| Combinatorial Logic | TruthTable |
| Constant | Value |
| Dead Zone | LowerValue,UpperValue |
| Derivative | CoefficientInTFapproximation |
| Discrete-Time Integrator | gainval,InitialCondition,UpperSaturationLimit,LowerSaturationLimit |
| Gain | Gain |
| Hit Crossing | HitCrossingOffset |
| Initial Condition (IC) | Value |
| Integrator | InitialCondition,UpperSaturationLimit,LowerSaturationLimit,AbsoluteTolerance |
| n-D Lookup Table | |
| Magnitude-Angle to Complex | ConstantPart |
| Memory | InitialCondition |
| Permute Dimensions | Order |
| Quantizer | QuantizationInterval |
| Rate Limiter | RisingSlewLimit,FallingSlewLimit,InitialCondition |
| Rate Transition | InitialCondition |
| Real-Imag to Complex | ConstantPart |
| Relay | OnSwitchValue,OffSwitchValue,OnOutputValue,OffOutputValue |
| Saturation | UpperLimit,LowerLimit |
| Sine | Amplitude,Bias,Frequency,Phase,Samples,Offset |
| State-Space | A,B,C,D,X0,AbsoluteTolerance |
| Switch | Threshold |
| Transport Delay | DelayTime,InitialOutput,BufferSize,PadeOrder |
| Unit Delay | InitialCondition |
This check requires a Simulink Check™ license.
Check Parameterization
This check does not include sub-checks because the MAB modeling guideline provides only one sub ID.
For reference, the MAB guideline sub ID(s) that are recommended for use by the NA-MAAB and JMAAB modeling standards organizations are:
NA-MAAB — No recommendations
JMAAB — a
Open the Model Configuration Editor and search for check ID
mathworks.jmaab.jc_0645.Use the Allowed calibration values to define which values are acceptable for calibration variables in the model.
Use the Get Tunable Block Parameters corresponding to the Block Type table to add or delete block types and/or mask types that require calibration.
Click Apply and save the configuration.
Results and Recommended Actions
| Condition | Recommended Action |
|---|---|
| Improper usage of tunable block parameter values. | Change the tunable block parameter literal values to named constants. |
Capabilities and Limitations
Runs on library models.
Analyzes content in masked subsystems. By default, the input parameter Look under masks is set to
graphical.Analyzes content of library-linked blocks. By default, the input parameter Follow links is set to
on.Allows exclusions of blocks and charts.
Edit-Time Checking
This check is supported by edit-time checking.