Main Content

reset

R2026b

Reset internal states for ahrs10filter

Description

reset(FUSE) resets the State, StateCovariance, and internal integrators to their default values.

example

Examples

collapse all

Create an ahrs10filter object.

filter = ahrs10filter;

Predict the state of the filter based on an accelerometer reading of [1 1 1] m/s2 and a gyroscope reading of [1 1 0] rad/s. Display the filter state.

predict(filter,[1 1 1],[1 1 0]);
disp(filter.State')
    1.0000    0.0025    0.0025         0         0    0.0441         0         0         0         0         0         0   27.5550   -2.4169  -16.0849         0         0         0

Reset and display the filter state.

reset(filter)
disp(filter.State')
    1.0000         0         0         0         0         0         0         0         0         0         0         0   27.5550   -2.4169  -16.0849         0         0         0

Input Arguments

collapse all

Object of ahrs10filter.

Extended Capabilities

expand all

C/C++ Code Generation
Generate C and C++ code using MATLAB® Coder™.

GPU Code Generation
Generate CUDA® code for NVIDIA® GPUs using GPU Coder™.

Version History

Introduced in R2019a