Simscape Electrical conversion to Simulink and back

12 views (last 30 days)
Hello,
I have used Simulink for a long time but I am new to Simscape. I am trying to build a model of a DC motor controlled using a H Bridge. Just to try something out, I want to connect the BRK port of the H Bridge to a signal coming from Simulink, using the Simulink-PS convertor block. But I am unable to do so as you can see in the attached picture.
Is this not the right way to connect Simulink to PS?
Thanks,
Anish

Accepted Answer

David John
David John on 6 Dec 2021
BRK is an electrical signal, so it needs to come out of a voltage source instead of directly from a Simulink-PS Converter.
Try adding a Controlled Voltage Source between REF and BRK, and connect your Physical Signal to the control node.

More Answers (0)

Categories

Find more on Specialized Power Systems in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!