Hello,
I am trying to synchronize the reading of ADC with the interrupts coming from EOC of the same ADC. The model I have s simple. As configured below. I am getting the following error. Any help is appreciated.
0 Comments
Accepted Answer
Aditya Padmanabha
on 7 Feb 2020
Hi Zak,
Please set the properties of the signal at ADC output to Cla1DataRam memory so that the variable is created in cla.
Also ensure you have selected c28035_cla.cmd for Linker command file in Configuration parameters -> Hardware Implementation tab with Boot From Flash enabled.
Hope it helps,
Aditya