Why the Gibbs free energy of water -237.14kJ/mol is chosen to calculate the Nernst voltage in PEMFuelCellSystemExample, but not the one of water vapor -228.60 kJ/mol?
2 views (last 30 days)
Show older comments
In the code of FuelCell.ssc, the activity of water vapor (a_H2O_C, RH%) is utilized to calculate the Nernst voltage, but not the activity of liquid water(1).
so, is the Nernst voltage based on the product of liquid water, or water vapor?
1 Comment
Yifeng Tang
on 9 May 2025
Not sure ...
Using the liquid water value of -237.14kJ/mol gives me a standard potential of 1.2289V
G_H2O = -237.14e3 ; % J/mol
F = 96485.33212; % C/mol
E_cell = G_H2O/(-2*F) % V
This seems to agree well with references I found. For example https://users.encs.concordia.ca/~pillay/fuel-cells.html, Table 4.2.
Using -228.60 kJ/mol for G gives me 1.1846V instead.
G_H2O = -228.60e3 ; % J/mol
F = 96485.33212; % C/mol
E_cell = G_H2O/(-2*F) % V
Answers (0)
See Also
Categories
Find more on Simscape Fluids in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!