Processor-in-the-loop

2 views (last 30 days)
nour ouzeri
nour ouzeri on 8 Apr 2025
Commented: nour ouzeri on 23 Apr 2025
I am experiencing issues executing a Processor-in-the-Loop (PIL) simulation in Simulink for a model that incorporates Simscape blocks. Despite following standard procedures for PIL setup, the simulation does not run as expected. Are there specific configurations or considerations for integrating PIL with Simscape models that could resolve this problem?
Error:The selected system expresses connection ports. Subsystem based code generation is not supported for portions of physical models. In order to generate code, the physical model must exist entirely within a subsystem.

Accepted Answer

praguna manvi
praguna manvi on 15 Apr 2025
The following documentation link details some of the limitations of the code generation path for Simscape models used in PIL, which states that all blocks belonging to a given physical network must be placed in the same nonvirtual subsystem. For troubleshooting this issue, you can refer to various other limitations, such as the one mentioned above, here:
Additionally, for more information on how Simscape code generation differs from Simulink, refer to the following link:
  1 Comment
nour ouzeri
nour ouzeri on 23 Apr 2025
Can you give me an example that shows a plant that contains simscape blocs and then a PIL verification mode is executed?

Sign in to comment.