DataAcqusitionToolbox write has a delay

6 views (last 30 days)
Kevin
Kevin on 14 Jun 2023
Commented: Kevin on 15 Jun 2023
I am using a NI DAQ. I have code that follows this skeleton code:
dq = daq(...)
dq.addinput(...)
dq.addoutput(...)
dq.start();
tic
dq.write(some_output)
toc
The issue is that in this timer, MATLAB consistently takes ~ 0.7s longer than expected. For example, if my daq is running at a rate of 1000Hz, and my output is 3000 samples, total time to run would be ~3.7s, rather than an expected 3s.
Digging into the profiler, this seems to be due to just the delay required to start up the hardware for the daq or something related, but I would like to minimize or eliminate this delay. Any ideas?
  2 Comments
Mario Malic
Mario Malic on 14 Jun 2023
"If the DataAcquisition has both input and output channels, the input acquisition begins and ends at the same time as the output generation, resulting in the same number of scans."
Maybe your output signal is longer?
Kevin
Kevin on 15 Jun 2023
I've confirmed that my output signal should be the exact expected amount of time.

Sign in to comment.

Answers (1)

Mario Malic
Mario Malic on 14 Jun 2023

Categories

Find more on Data Acquisition Toolbox Supported Hardware in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!