simulink asynchronous machine rotor parameters
Show older comments
Hello, in the model of the asynchronous machine the rotor currents(ir_,ir_b,ir_c), voltages(v_ra,v_rb, v_rc) and inductances are already referred to the stator or not? I mean the values in the simulink output of the block containing the measurement signals. Thanks
Answers (1)
Sabin
on 12 Aug 2025
0 votes
In the Induction Machine Wound Rotor block, the rotor circuit is referred to the stator. Therefore, when you use the block in a circuit, refer any additional circuit parameters to the stator.