Linear FM Waveform
Linear FM (LFM) pulse waveform
Libraries:
Phased Array System Toolbox /
Waveforms
Description
The Linear FM Waveform block generates a linear FM pulse waveform with specified pulse width, pulse repetition frequency (PRF), and sweep bandwidth. The block outputs an integer number of pulses or samples.
Ports
Input
Index to select the pulse repetition frequency (PRF), specified as a positive integer. The index selects the PRF from the predefined vector of values specified by the Pulse repetition frequency (Hz) parameter.
Example:
4
Dependencies
To enable this port, select Enable PRF selection input.
Data Types: double
Frequency offset in Hz, specified as a scalar.
Example:
2e3
Dependencies
To enable this port, set Source of Frequency Offset to
Input port
.
Data Types: double
Output
Pulse waveform samples, returned as a complex-valued vector.
Data Types: double
Pulse repetition frequency of current pulse, returned as a positive scalar.
Dependencies
To enable this port, set the Output signal
format parameter to Pulses
and then select the Enable PRF output
parameter.
Data Types: double
Matched filter coefficients, returned as a vector or matrix.
Dependencies
To enable this port, select Enable Matched Filter Coefficients Output.
Data Types: double
Complex Number Support: Yes
Parameters
Sample rate of the output waveform, specified as a positive scalar. The ratio of Sample rate (Hz) to each element in the Pulse repetition frequency (Hz) vector must be an integer. This restriction is equivalent to requiring that the pulse repetition interval is an integral multiple of the sample interval.
Programmatic Use
Block
Parameter:SampleRate |
Type:double |
Values:positive scalar |
Default:1e6 |
Method to set the pulse duration, specified as Pulse width
or Duty cycle
. When you set this parameter to
Pulse width
, the pulse duration is set using the
Pulse width (s) parameter. When you set this parameter to
Duty cycle
, the pulse duration is computed from the
values of the Pulse repetition frequency (Hz) and Duty
Cycle parameters.
Programmatic Use
Block
Parameter:DurationSpecification |
Type:string |
Values:string |
Default:'Pulse
width' |
The duration of each pulse, specified as a positive scalar. Set the product of Pulse width (s) and Pulse repetition frequency to be less than or equal to one. This restriction ensures that the pulse width is smaller than the pulse repetition interval. Units are in seconds.
Example: 300e-6
Dependencies
To enable this parameter, set the Method to specify pulse
duration parameter to Pulse width
.
Programmatic Use
Block
Parameter:PulseWidth |
Type:double |
Values:string |
Default:50e-6 |
Waveform duty cycle, specified as a scalar in the range [0,1].
Example: 0.7
Dependencies
To enable this parameter, set the Method to specify pulse duration
parameter to Duty cycle
.
Programmatic Use
Block
Parameter:DutyCycle |
Type:double |
Values:positive scalar |
Default:1e6 |
Pulse repetition frequency, PRF, specified as a scalar or a row vector. Units are in Hz. The pulse repetition interval, PRI, is the inverse of the pulse repetition frequency, PRF. The value of Pulse repetition frequency (Hz) must satisfy these constraints:
The product of Pulse width and Pulse repetition frequency (Hz) must be less than or equal to one. This condition expresses the requirement that the pulse width is less than one pulse repetition interval. For the phase-coded waveform, the pulse width is the product of the chip width and number of chips.
The ratio of sample rate to any element of Pulse repetition frequency must be an integer. This condition expresses the requirement that the number of samples in one pulse repetition interval is an integer.
You can select the value of PRF by using block parameter settings alone or
in conjunction with the input port, PRFIdx
.
When the Enable PRF selection input parameter is not selected, set the PRF using block parameters.
To implement a constant PRF, specify Pulse repetition frequency (Hz) as a positive scalar.
To implement a staggered PRF, specify Pulse repetition frequency (Hz) as a row vector with positive values. After the waveform reaches the last element of the vector, the process continues cyclically with the first element of the vector. When PRF is staggered, the time between successive output pulses cycles through the successive values of the PRF vector.
When the Enable PRF selection input parameter is selected, you can implement a selectable PRF by specifying Pulse repetition frequency (Hz) as a row vector with positive real-valued entries. But this time, when you execute the block, select a PRF by passing an index into the PRF vector into the
PRFIdx
port.
In all cases, the number of output samples is fixed when you set the
Output signal format to Samples
. When you
use a varying PRF and set Output signal format to
Pulses
, the number of output samples can vary.
Programmatic Use
Block Parameter:PRF |
Type:double |
Values:positive scalar |
Default:1e6 |
Select this parameter to enable the PRFIdx
port.
When enabled, pass in an index into a vector of predefined PRFs. Set predefined PRFs using the Pulse repetition frequency (Hz) parameter.
When not enabled, the block cycles through the vector of PRFs specified by the Pulse repetition frequency (Hz) parameter. If Pulse repetition frequency (Hz) is a scalar, the PRF is constant.
Programmatic Use
Block
Parameter:PRFSelectionInputPort |
Type:logical |
Values:positive scalar |
Default:off |
Bandwidth of the linear FM sweep in Hz, specified as a positive scalar.
Example: 1e3
Specify the direction of the linear FM sweep as Up
(increasing frequency) or Down
(decreasing
frequency).
FM frequency sweep interval, specified as
Positive
or
Symmetric
. If you set this parameter to
Positive
, the waveform sweeps the frequency
interval between 0 and B, where
B is the value of the Sweep
bandwidth parameter. If you set this parameter value to
Symmetric
, the waveform sweeps the interval
between –B/2 and B/2.
FM signal amplitude envelope, specified as
Rectangular
or
Gaussian
.
Source of frequency offset, specified as Property
or
Input port
.
When set to
Property
, the offset is determined by the value of the Frequency Offset parameter.When set to
Input port
, the offset is determined by the value of the FreqOffset port.
Programmatic Use
Block
Parameter:FrequencyOffsetSource |
Type:enum |
Values:Property ,
Input Port
|
Default:Property |
Frequency offset, specified as a scalar. Units are in Hz.
Example: 2e3
Dependencies
To enable this parameter set the Source of Frequency Offset
parameter to Input port
.
Programmatic Use
Block
Parameter:FrequencyOffset |
Type:double |
Values:scalar
|
Default:0 |
Source of simulation sample time, specified as Derive from waveform
parameters
or Inherit from Simulink engine
.
When set to Derive from waveform parameters
, the block runs
at a variable rate determined by the PRF of the selected waveform. The elapsed time is
variable. When set to Inherit from Simulink engine
, the
block runs at a fixed rate so the elapsed time is a constant.
Dependencies
To enable this parameter, select the Enable PRF selection input parameter.
Programmatic Use
Block
Parameter:SimulationTimeSource |
Type:enum |
Values:Derive from waveform
parameters , Inherit from Simulink
engine |
Default:Derive from waveform
parameters |
The format of the output signal, specified as Pulses
or Samples
.
If you set this parameter to Samples
, the output of the block consists of multiple samples. The number of samples is the value of the Number of samples in output parameter.
If you set this parameter to Pulses
, the output of the block consists of multiple pulses. The number of pulses is the value of the Number of pulses in output parameter.
Programmatic Use
Block
Parameter:OutputFormat |
Type:enum |
Values:Pulses
Samples |
Default:Pulses |
Number of samples in the block output, specified as a positive integer.
Example: 1000
Dependencies
To enable this parameter, set the Output signal format
parameter to Samples
.
Programmatic Use
Block
Parameter:NumSamples |
Type:double |
Values:positive
scalar
|
Default:100 |
Data Types: double
Number of pulses in the block output, specified as a positive integer.
Example: 2
Dependencies
To enable this parameter, set the Output signal
format parameter to
Pulses
.
Programmatic Use
Block
Parameter:NumPulses |
Type:double |
Values:positive
scalar
|
Default:1 |
Data Types: double
Select this parameter to enable the PRF
output port.
Dependencies
To enable this parameter, set Output signal format to
Pulses
.
Programmatic Use
Block
Parameter:PRFOutputPort |
Type:enum |
Values:off
on |
Default:off |
Select this parameter to enable the Coeff
output port.
Programmatic Use
Block
Parameter:CoefficientOutputPort |
Type:enum |
Values:off
on |
Default:off |
Block simulation, specified as Interpreted Execution
or
Code Generation
. If you want your block to use the
MATLAB® interpreter, choose Interpreted Execution
. If
you want your block to run as compiled code, choose Code
Generation
. Compiled code requires time to compile but usually runs
faster.
Interpreted execution is useful when you are developing and tuning a model. The block
runs the underlying System object™ in MATLAB. You can change and execute your model quickly. When you are satisfied
with your results, you can then run the block using Code
Generation
. Long simulations run faster with generated code than in
interpreted execution. You can run repeated executions without recompiling, but if you
change any block parameters, then the block automatically recompiles before
execution.
This table shows how the Simulate using parameter affects the overall simulation behavior.
When the Simulink® model is in Accelerator
mode, the block mode specified
using Simulate using overrides the simulation mode.
Acceleration Modes
Block Simulation | Simulation Behavior | ||
Normal | Accelerator | Rapid Accelerator | |
Interpreted Execution | The block executes using the MATLAB interpreter. | The block executes using the MATLAB interpreter. | Creates a standalone executable from the model. |
Code Generation | The block is compiled. | All blocks in the model are compiled. |
For more information, see Choosing a Simulation Mode (Simulink).
Programmatic Use
Block Parameter:
SimulateUsing |
Type: enum |
Values:
Interpreted Execution , Code
Generation |
Default:
Interpreted Execution |
Version History
Introduced in R2014b
See Also
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: United States.
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)