- if you are giving 60 as i/p using binary point scaling to 2^30 will given as 64424509440 (scaled value).
Issue with fixed point code generation
2 views (last 30 days)
Show older comments
Hi,
In fixed point model, inputs values are provided as 60,110,150,160,20,166,130. Expected result is 200 and it is shown exactly in simulation result.
But in generated code, the input values are displayed as 503316480,922746880,1258291200,1342177280,167772160,1392508928,1090519040 correspondingly. Result is displayed as 1677721600 instead of 200.
Please provide feedback on this.
0 Comments
Answers (1)
Muruganandham Subramanian
on 28 May 2013
Edited: Muruganandham Subramanian
on 28 May 2013
Hi,
In fixedpoint operation, you might used scaling either binary point or slope and bias, So the value which you given as i/p(depends scaling value) and o/p (depends scaling value) should be divided finally.
e.g..
So finally If you divide by the scaled value, you can get your expected result
i.e.
Exp.result=Actualresult/Scaled value
3 Comments
See Also
Categories
Find more on Simscape Electrical in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!