Network coupler for gas
19 views (last 30 days)
Show older comments
Hello. Does anywhere exist the network coupler for gas? I don’t see it in the simscape library. See the attachment. I need this element to split a gas model on 2 parts to simplify solving on real-time machine. Did anybody come across with this issue? Thanks.
0 Comments
Answers (1)
Yifeng Tang
on 20 Nov 2024 at 17:57
Network coupler for Gas or Moist Air domain doesn't exist as of R2024b.
I see two options:
(1) follow the structure of such component for the TL domain, and write your own coupler for the Gas domain. The key component is the "partialChamber". You may compare it to the regular constant volume chamber and understand the type of change needed to be made for the Gas domain.
(2) ask yourself whether the original model has been optimized numerically and whether splitting it is the only path forward. More details, e.g. an attached model, will help clarify on this.