Main Content

Troubleshoot Signal Data Logging from Inport in Referenced Model

A model contains referenced models. The referenced models have root-inport signals that would be helpful to log and stream to the Simulation Data Inspector for visualization. When these signals are marked in the model for logging, a warning occurs in the diagnostic viewer when building the model:

Warning: Streaming to the SDI is not available for signal at
<sldiag objui="outport" objparam="1" objname="{'A/B',
'B/b1'}">output port 1</sldiag> of block '{'A/B', 'B/b1'}'.
Add a SignalCopy block at that port and instrument the
SignalCopy output port.

What This Issue Means

The warning message reports that the root-inport signals of referenced models are not available for streaming. Within top model A, the referenced model root inports that generate this warning message appear in referenced model A/B and referenced model A/B/C.

Top Model A

From top model A, root-inport signals from referenced models are not available for logging.

Referenced Model A/B

From top model A, root-inport signals from referenced models are not available for logging.

Referenced Model A/B/C

From top model A, root-inport signals from referenced models are not available for logging.

Try This Workaround

To instrument a root-inport signal in a referenced model and stream the signal to the Simulation Data Inspector, you can connect the signal to a Signal Conversion block that you configure as a Signal Copy block. Mark the output of the Signal Copy block for logging to the Simulation Data Inspector.

Related Examples

More About