Support Limitations of Simulink Design Verifier for Simulink Software Features
Simulink® Design Verifier™ does not support the following Simulink software features. Avoid using these unsupported features.
| Not Supported | Description | 
|---|---|
Variable-step solvers  | The software supports only fixed-step solvers. For more information, see Fixed Step Solvers in Simulink.  | 
Callback functions  | The software does not execute model callback functions during the analysis. The results that the analysis generates, such as the harness model, may behave inconsistently with the expected behavior. 
  | 
Model callback functions  | The software supports model callback functions only if the   | 
Algebraic loops  | The software does not support models that contain algebraic loops. For more information, see Algebraic Loop Concepts.  | 
Masked subsystem initialization functions  | The software does not support models whose masked subsystem initialization: 
 
  | 
Variable-size signals  | The software supports test generation for models with bounded variable-size signals. For more information on how to generate test cases when input signals are of variable-size, see Achieve Coverage in Models with Variable-Size Inputs. In addition, the following are the limitations for analysis: 
 
 Note 
  | 
Unbounded variable-size signals  | Not supported. | 
Multiword fixed-point data types  | The software does not support multiword fixed-point data types larger than 128 bits.  | 
Half data type  | The software does not support variables of half data type.  | 
Nonzero start times  | Although Simulink allows you to specify a nonzero simulation start time, the analysis generates signal data that begins only at zero. If your model specifies a nonzero start time: 
  | 
Nonfinite data  | The software does not support nonfinite data (for example,  In the Relational Operator block, the software assigns the output as follows: 
 In the MATLAB Function block, the software assigns the return value as follows: 
 
  | 
Concurrent execution  | The software does not support models that are configured for concurrent execution.  | 
Signals with nonzero sample time offset  | The software does not support models with signals that have nonzero sample time offsets.  | 
Models with no output ports  | The software only supports models that have one or more output ports. If a model contains test condition or test objective blocks and no output ports are present in the model, then nominal test cases will be generated.  | 
Large floating-point constants outside the range   | The use of large floating-point constants can cause out of memory errors or substantial loss of precision. Avoid using such constants if possible.  | 
Symbolic Dimensions  | The software does not support symbolic dimensions for test generation, property proving, or design error detection.  | 
| Simulink Strings | Models that contain blocks with string data types as block parameters are not supported. For more information, see Simulink Strings.  | 
Parameter Tuning  | 
 
 
  | 
| Row-major Algorithms | The software does not support models that contain MATLAB System
                            blocks that use   | 
Block Execution Order  | The software does not support models with blocks having
                                  |