RS485 properties
Use the RS485 properties to configure the baud rate for communication and control pin connections of the RS485 network.
You can set these parameters to configure the RS485 properties.
Serial Module
Select the type of serial module or port that the block will use for Modbus® communication.
Settings
Default:
Serial 1
BaudRate
Set the baud rate of the serial port on the Arduino® hardware for the RS485 serial communication.
Settings
Default:
9600
Configuration
Select the data frame configuration for the RS485 Modbus communication blocks. The first digit indicates the number of bits in each data packet. The second digit indicates the parity bits present in the data packet. The last digit indicates the number of stop bits in each data packet. For example,
SERIAL_8N1
indicates 8-bit data communication with no parity bits and one stop bitSERIAL_5E1
indicates 5-bit data communication with even parity bits and one stop bitSERIAL_6O2
indicates 6-bit data communication with odd parity bits and two stop bits
Settings
Default:
SERIAL_8N1
SERIAL_5N1
, SERIAL_6N1
,
SERIAL_7N1
,
SERIAL_5N2
, SERIAL_6N2
,
SERIAL_7N2
,
SERIAL_8N2
, SERIAL_5E1
,
SERIAL_6E1
,
SERIAL_7E1
, SERIAL_8E1
,
SERIAL_5E2
,
SERIAL_6E2
, SERIAL_7E2
,
SERIAL_8E2
,
SERIAL_5O1
, SERIAL_6O1
,
SERIAL_7O1
,
SERIAL_8O1
, SERIAL_5O2
,
SERIAL_6O2
,
SERIAL_7O2
,
SERIAL_8O2
DE Pin
Enter the data enable pin number associated with the RS485 shield.
Settings
Default:
8
RE Pin
Enter the receive enable pin number associated with the RS485 shield.
Settings
Default:
9