ssSetParameterTuningCompliance
Specify sample time behavior and tunability for S-function blocks with port-based sample times
Syntax
void ssSetParameterTuningCompliance(SimStruct *S,logical Flag)
Arguments
SSimStruct that represents an S-function block.
FlagLogical value indicating whether to allow a sample time of
Inffor ports in the S-function.
Description
Use this macro to specify sample time behavior for your S-function with port-based
sample times. If you set flag to False, the
Simulink® engine does not allow a sample time of Inf for this
S-function. If you set flag to True, the
S-function block is tunable and its ports can have a sample time of
Inf. To set the sample time for ports in the S-Function, use
ssSetOutputPortSampleTime and
ssSetInputPortSampleTime. These
ports execute every time you tune any parameter in your model during
simulation.
Languages
C, C++
See Also
Version History
Introduced in R2015b