ssGetPortBasedSampleTimeBlockIsTriggered
Determine whether a block that uses port-based sample times resides in a triggered subsystem
Syntax
boolean_T ssGetPortBasedSampleTimeBlockIsTriggered(SimStruct *S)
Arguments
SSimStruct that represents an S-Function block.
Returns
The Boolean value true if S uses port-based
sample times and resides in a triggered subsystem. Otherwise, returns
false.
Description
Use this macro in mdlOutputs and mdlUpdate to decode whether to use
the block's triggered or nontriggered algorithms to compute its states and
outputs.
Note
This macro returns a valid result only after sample time propagation. Thus,
you cannot use it in mdlSetInputPortSampleTime and
mdlSetOutputPortSampleTime to
determine whether a port's sample time is triggered. Use ssSampleAndOffsetAreTriggered instead.
Languages
C, C++
Examples
See the S-function sfun_port_triggered.c used in sfcndemo_port_triggered.