Twelve-Pulse Gate Multiplexer

Multiplex gate input signals to Three-Level Converter (Three-Phase) block

  • Twelve-Pulse Gate Multiplexer block

Libraries:
Simscape / Electrical / Semiconductors & Converters / Converters

Description

The Twelve-Pulse Gate Multiplexer block routes gate voltage signals to the 12 switching devices in a Three-Level Converter (Three-Phase) block. The block multiplexes the 12 gate signals into a single vector. Gate signals are ordered as a-phase, b-phase, and then c-phase, with four gate signals per phase.

When you switch the block inputs to electrical ports, the block shows 12 pairs of electrical connections, each pair corresponding to the gate and cathode of a switching device.

Ports

Input

expand all

Physical signal ports associated with the gate terminals of the Three-Level Converter (Three-Phase)a-phase switching devices.

Dependencies

To enable this port, set Gate-control port to PS.

Physical signal ports associated with the gate terminals of the Three-Level Converter (Three-Phase)b-phase switching devices.

Dependencies

To enable this port, set Gate-control port to PS.

Physical signal ports associated with the gate terminals of the Three-Level Converter (Three-Phase)c-phase switching devices.

Dependencies

To enable this port, set Gate-control port to PS.

Conserving

expand all

Electrical conserving ports associated with the gate terminals of the Three-Level Converter (Three-Phase)a-phase switching devices.

Dependencies

To enable this port, set Gate-control port to Electrical.

Electrical conserving ports associated with the gate terminals of the Three-Level Converter (Three-Phase)b-phase switching devices.

Dependencies

To enable this port, set Gate-control port to Electrical.

Electrical conserving ports associated with the gate terminals of the Three-Level Converter (Three-Phase)c-phase switching devices.

Dependencies

To enable this port, set Gate-control port to Electrical.

Vector output port associated with the multiplexed gate signals. Connect this port to the G port of the Three-Level Converter (Three-Phase) block.

Electrical conserving ports associated with the individual cathode terminals corresponding to the Three-Level Converter (Three-Phase) block a-phase switching devices.

Dependencies

To enable this port, set Gate-control port to Electrical.

Electrical conserving ports associated with the individual cathode terminals corresponding to the Three-Level Converter (Three-Phase) block b-phase switching devices.

Dependencies

To enable this port, set Gate-control port to Electrical.

Electrical conserving ports associated with the individual cathode terminals corresponding to the Three-Level Converter (Three-Phase) block c-phase switching devices.

Dependencies

To enable this port, set Gate-control port to Electrical.

Parameters

expand all

Whether to expose PS or electrical control ports.

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Version History

Introduced in R2014b

expand all